skiascopeenUK
ski·a·scope S0448400 (skī′ə-skōp′)n. See retinoscope. [Greek skiā, shadow + -scope.]skiascope (ˈskaɪəˌskəʊp) n (Medicine) med a medical instrument for examining the eye to detect errors of refraction. Also called: retinoscope See also retinoscopy[C19: from Greek skia a shadow + -scope]skiascopeenUK
skiascope[′skī·ə‚skōp] (optics) An instrument used to study optical refraction within the eye. skiascopeenUK
skiascope (skī′ə-skōp′)n. See retinoscope.retinoscope An instrument for determining objectively the refractive state of the eye. It consists of a light source, a condensing lens and a mirror. The mirror is either semi-transparent or has a hole through which the retinoscopist can view the patient's eye along the retinoscope's beam of light. A patch of light is formed on the patient's retina and by moving that patch in a given direction and observing the direction in which it appears to move after refraction by the patient's eye, the retinoscopist can determine whether the patient's retina is focused in front of, at, or behind the retinoscope's sight hole. If the light reflected from the patient's fundus (called the retinoscopic reflex or light reflex) and observed in the patient's pupil through the retinoscope moves in the same direction as the movement of the mirror (this is referred to as a with movement), the eye is hyperopic. If the reflex moves in the opposite direction to that of the mirror (against movement), the eye is myopic. Sometimes it is impossible to see a clear movement one way or the other but only a bipartite reflex, showing opposite movements in the two sectors of the pupils (this is called a split reflex or a scissors movement). The refractive error is determined by placing lenses of various powers in front of the patient's eye until no movement is seen, i.e. the whole pupil is either illuminated or dark and the image of the patient's retina is then conjugate with the plane of the retinoscope's sight hole. When this phenomenon occurs the neutral point has been reached. The neutral point is measured for each principal meridian of the eye if it is astigmatic. To arrive at the patient's error of refraction the dioptric power corresponding to the distance between patient and retinoscope (called the working distance) is subtracted from the total lens power used to obtain neutralization. The amount of dioptric power subtracted is called the allowance. (Fig. R13) Syn. skiascope. See retinoscopic band; chromoretinoscopy; fundus reflex; velonoskiascopy. spot retinoscope A retinoscope that projects a circular beam of light upon the patient's retina. streak retinoscope A retinoscope that projects into the patient's eye an oblong streak, which can be adjusted in width and rotated in various meridians. It is more efficient than the spot retinoscope in determining astigmatism." >Fig. R13 Optical principle of a retinoscope (O, observer's eye; P, patient's eye; M, semi-silvered mirror) |